Newsgroups: comp.sys.transputer
From: jan@neuroinformatik.ruhr-uni-bochum.de (Jan Vorbrueggen)
Subject: Re: Dynamic Link Reconfiguration Problem
Organization: Institut fuer Neuroinformatik, Ruhr-Universitaet Bochum, Germany
Date: 25 Mar 94 11:40:43 GMT
Message-ID: <JAN.94Mar25124043@thalia.neuroinformatik.ruhr-uni-bochum.de>

You say that no communication is going on when you reconfigure, but your post
doesn't make clear how you enforce that. And this point is vital: T8 links
won't notice (in the sense T9 links) do that something happened to their wires
if it is at the wrong moment, and all you'll get is a deadlock. It is very
difficult to do what you want, and without overpowering reasons, I wouldn't
even attempt this.

	Jan